<Error>
<ErrorNumber>17700</ErrorNumber>
<ErrorFamily>Exposure Head</ErrorFamily>
<ErrorMessage>
HEAD: Only the safety loop detected by the head has closed
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Thermal</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The write laser safety interlock switch, detected by the WLC, is not closed,
although the focus laser interlock, detected by the HC, is closed.  This is
probably due to a problem with the interlock switch mechanism.
</text></DescriptionText>
<DescriptionText><text>
This error code applies to Thermal Head firmware version 1.34 and above.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Ensure that all safety interlock switches are properly closed.
</text></DescriptionText>
</OperatorAction>
<Cause>
A problem with the interlock switch mechanism.
</Cause>